Author Archives: nextcoffee

Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1000L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 11000kg External Dimensions 400x210x300cm(without chimney) HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-03-22

Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious  medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during  viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care waste  for laboratories, small clinics, and hospitals treating patients of the Novel Coronavirus (COVID-19) such as linens, sharps, gauze, gowns, etc. dav dav Related Waste Incinerator 500kg/day burn capacity incinerator cytotoxic waste animal crematory equipment www.clover-incinerator.com Tags incinerator incinerators waste HICLOVER.COM https://www.youtube.com/watch?v=BxiEa3XYvBs Contact Us Tel: +86-25-8461 0201 Mobile: +86-138139 31455 WhatsApp: 008613813931455 Twitter ID: @hiclovercom Wechat: 008613813931455 Website1: www.hiclover.com Website2: www.clover-incinerator.com Email1: [email protected] Email2: [email protected] Email3: [email protected] Email4: [email protected] Incinerator Video https://www.youtube.com/watch?v=CDdacp1wk1A Medical Environmental Waste Incinerator Waste Incinerators Recent Posts animal incinerator prices pet incinerator deisel large animal incinerators pet incinerators animal crematory equipment NCV…

Read more

Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic)  01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control

De manera atenta solicito me colabore con la cotizacion del incinerador incluyendo envió.Puri group a hospitality business in Indonesia is interested to introduce renewable energy in Indonesia or to use the energy sources for its facility around Indonesia. Kindly request to have more information on incinerator technology as it is needed to process 100 ton to 500 ton waste aday. In the Frame of our Specialized Projects Management, we are currently in search for supplier of Waste Incineration system for hazardous waste, the incineration system will be used for incineration of Prohibited Drugs and toxic materials, waste poultry, Dead Animals “cows, goats”, Spoiled vegetables, Etc. at customs Ports. For that we would like to request for your technical and Financial Proposal for supply , installation and Commissioning of Hazardous Waste Incineration system with incineration capacity of at least 400 Kg/ hr. Page | 3 The proposal should include the complete…

Read more

an incinerator for our dental clinics.The incinerator must comply with ” Technical Standard NTON 05-015-02 Management and Solid Waste Disposal Hazardous co go ” , in addition to meeting international standards functionality standards for new stationary sources and emissions from the Environmental Protection Agency United States ( Environmental Protection Agency EPA ) Incinerators Medical and Hospital infectious waste ( HMIWI its acronym in English ) and the standards of the World Health Organization (WHO ) . According to point 8.5.1.3 of the NTON 05-015-02 incinerator must have the following: ” Incinerators equipped with a camera primary and a secondary combustion , equipped with burners capable of achieving complete combustion of waste and widespread destruction of harmful and toxic chemicals (dioxins and furans among others) , attached to the solid waste bioinfectious . a) primary combustion chamber , it requires a temperature of 800 ° C and one hour dwell to…

Read more

an incinerator suitable for chemcial waste containers. capacity about 100 kgs per hour with a scrubber.1- One system of medical waste materials incinerator – Capacity : 100 kg –  Fuel : gas oil 2- One system of normal waste materials incinerator –  Capacity : 150 kg –   Fuel : gas oil this kind of capacity will be a waste combustion central for a small city. you can find other company. our products main for small waste output. for hospital directly, local at hospital, or portable/mobile incinerator to one site when end-customer request. incinerator without smoke and smelting for the environment. capapcity 500kg per day. Could you specify the point of oil fuel? By this you mean petrol or diesel? with dieseil burner.we managed to get a walk in Algeria, and we hope to export to other countries in Africa. we specify that we are interested in mobile incinerators for hospital…

Read more

Incinerator but the size of chamber > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr. Fueled by Heavy OIL Burner.waste disposal incinerator, capable of handling both wet and dry garbage.. Which include house hold wastes and dry leaves. The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a given time. edical Waste Incinerators. The mobile unit is our priority then the fixed units. Medical Waste Incinerators. The mobile unit is our priority then the fixed units. a;  Batch Capacity for each model, how much load can we put in one time. I need tio under stand in term of batch load one time I can ut in Kgs. b:  Burning capacity per hour, to know how much time it will take to burn one batch and what is cooling timem for each one. c: How many batch…

Read more

2 medical waste incinerators model YD-50, 150 kg feed capacity, 220/380 V, 50 Hz c/w 5 mtr. chimney. Bio-medical waste management plant requirements: Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal units and flue gas treatment systems, with the following details: Hourly capacity of the system:           from 250 up to 500 Kgs/ hour Duration of operation:                        from 14 up to 18 hrs/ day Fuel type to be used:                         Diesel or alternative Calorific value of the waste:               3500 up to the maximum limit kcal/ Kg Minimum operating temperature of primary chamber: 1000 degrees celcius a smaller  capacity of 150 to 250  kg/feed capacity will be good for comparison. Our main byproducts are the slaughtered unwanted carcass. •             Using diesel as fuel •             Capacity 50kg per hour •             chambers material: Refractory Concrete •             Number of chambers: Two •             Manual feed solicito un horno crematorio para…

Read more

50 kg/  hour  capacity incinerators ·        Burning Rate: 50kos/hr ·        Feed Capacity:  150kqs ·        Primary  Combustion  Chamber:  900 liters ·        Secondary  Combustion  Chamber:  300 liters ·        Mix Combustion  Chamber:  Yes ·        Smoke Filter Chamber:  Yes ·        Feed Mode: Manual ·        Power: 0.7Kw ·        Fuel Type: Diesel Oil/ Natural Gas/LPG ·        Internal Dimensions:  120 x 90 x 85cm (primary  chamber) ·        External  Dimensions:  200 x 160 x 310cm (without  chimney) ·        Burning  Efficiency:  >98% small  scale medical waste  incinerators.The required burning capacity of those incinerators are 10 kg and 15 kg/hr .The fuel oil using for those incinerator is diesel oil .

20/3705