Author Archives: nextcoffee

Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 28 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1400L Feed Door 90x80cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 15000kg External Dimensions 400x210x300cm(without chimney) The air supply should be controlled efficiently; Flame contact with all the gases should be achieved; The minimum combustion temperature of the primary chamber should not be less than 850°C; The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply. The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm. The following conditions should be met in…

Read more

Small-Scale Medical Waste Incinerators in Togo Togo, a small West African nation, is experiencing steady development in its healthcare sector, with growing awareness about safe medical waste disposal. Clinics, regional hospitals, and rural health posts are increasingly seeking affordable, efficient solutions for disposing of infectious waste, used syringes, contaminated dressings, and expired pharmaceuticals. Among the solutions, small-capacity medical waste incinerators like the HICLOVER TS10, TS20, and TS30 series have found practical and effective applications. Let’s explore why these systems are being chosen and what makes them suitable for Togo’s healthcare facilities.  Current Situation of Medical Waste in Togo In Togo, most medical waste is generated by: Regional hospitals in cities like Lomé, Sokodé, Kara, and Atakpamé Private clinics and small maternity wards Health posts spread across rural areas Traditionally, open burning or shallow burial was common practice—methods that pose serious risks of groundwater contamination, air pollution, and disease transmission. Recent…

Read more

Incinerators to be suitable for the professional disposal of clinical & medical waste / garbage with a higher load capacity in the range of approximately 1000-1500 Kg.  The durable, self-contained incinerators shall offer an effective and highly efficient, safe disposal and to be manufactured according to applicable international directives, e.g. CE, EU, etc. Type of Fuel: Diesel or Petrol or Natural Gas. Temperature controlled, efficient burner for optimum fuel economy. incinerator in the best technology and an approximate capacity of 2000 ton / year. Possibly an incineration capacity of 200 kg / hr and a calorific value of 7500 kcal / kg. Industrial and domestical waste.INCINERATOR For incineration of Laboratory wastes materials Features i.Smoke and smell free ii.High Temperature , refractory lining with excellent heat retention iii.Quick heat up time iv.Must have a secondary chamber v.Constant run fan vi.Temperature monitoring vii.Thermostat Control Technical Specifications i.Capacity :                    approx. 0.20 m3 ii.Fuel…

Read more

Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate 60-80 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 20.4 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1100L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 6000kg External Dimensions 260x150x180cm The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel  fuel as a supplemental fuel oil. It should incorporate an Air Pollution Control (APC) System suitable for basic emission control. The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid  deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several  variations of…

Read more

HICLOVER Containerized Incinerators for Biohazard Waste Treatment As part of its mandate to improve health and environmental safety, UNOPS is sourcing two high-capacity, containerized biohazard waste incinerators for its operations in South Sudan. These units must enable the safe on‑site destruction of biological samples and materials that pose risks to human health and the environment. HICLOVER’s TS200 and TS300 models are ideally suited to meet these requirements. Why HICLOVER Incinerators Are the Right Choice Containerized, Plug‑and‑Play Design • Delivered in a single ISO container for rapid deployment • No permanent foundation required—ideal for remote or emergency field sites • Secure, weather‑resistant steel enclosure protects internal systems Top‑Loading Combustion Chamber • Large top‑loading door simplifies batch feeding of bulky biohazard waste • Reduces operator exposure and speeds up loading cycles • Optional front or side feeding doors available for site‑specific workflows Reliable PLC‑Automatic Control • Fully automated temperature and combustion control…

Read more

Items/Model TS50(PLC) Picture Principle Solid Waste Incineration Burn Rate 30-45 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 13.3 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 800L Feed Door 70x55cm Chimney 5Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 4500kg External Dimensions 230x130x155cm HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: [email protected] Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-03-21

It should  be  a three chambered incinerator The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in…

Read more

Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption (Oil) Average 20.4 Kgs/Hour Internal Dimensions 100x80x70cm (Primary Combustion Chamber) External Dimensions 230 x 130 x 155cm (main body) Waste combustion chamber 560Liters Post Combustion Chamber 280Liters Oil Tank Capacity 200 Liters Door Opening 70 x 50cm Chimney 5.0M Gross Weight 4500kgs Chamber Material Firebrick ,Refractory Concrete Max. Heat Value 166,000Kcal/Hr. Operation Technical Specifications Solid Chamber temperature 8000C -10000C Gas Chamber temperature 10000C -12000C Chamber Anti-Rate 17500C Residency time 2.0 Sec. Burning efficiency >98% Waste Lower Calorific Power 3000Kcal HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201   …

Read more

A PYROLYTIC MEDICAL WASTE INCINERATOR FOR   REMERA-MBOGO DISTRICT HOSPITAL An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The incinerator should meet the environment standards. The final destination of this equipment is Remera-Mbogo Special Health Center in RULINDO District; bidders are requested to respond to the following requested technical specifications with comprehensive description of equipment being offered. The tenderer is also requested to bid on both equipment and shelter, and he/she will be responsible of both. All pre-installation works have to be done by the tenderer, better to conduct a sit visit before bidding. The bidder has also to provide original catalogue not a copy. N°    Expected Technical specifications    Technical specifications from the bidder 2.01 The incinerator shall be fully self contained. 2.02 The incinerator plant shall incorporate a control panel for its operation. On the control panel…

Read more

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service. Refractory cement,Ignition transformer – Secondary burner,Ignition transformer – Primary burner,Emergency push button,Temperature thermos couple with Locknut – 1600oC,Temperature thermos couple with Locknut – 1300oC,Temperature display controller – Secondary Chamber,Temperature display controller – Primary Chamber (Parameter – Digital Adjust Instrument),Burner Lighting Sensor (Photo Cell) PBT/PC Circuit board (LM44.255C2BT) High Stage Secondary,Circuit board (LOA24.171B2BT) Primary Fire proof flange gasket,Fire proof flange gasket CA50-600,EB14HPM,26-48-3371T JT04,K1600,k1300,XMT – 3000,XMT – 2000 QRB1,LM44.255C2BT,LOA24.171B2BT,SN834457 8023020001,SN834451,3713798,AS47B,FO03,BTL20,SPARK35 Ignition electrode with leads(for burner BTL20/SPARK35),Solenoid(for burner BTL20/SPARK35),Burner fuel pump(for burner BTL20/SPARK35),Fuel filter(for burner BTL20/SPARK35) Burner – Baltur,Burner – Baltur,Solenoid,Burner fuel pump Ignition Cable,Ignition…

Read more

90/3582