Category Archives: Blog

hazardous waste high temperature incinerators for the treatment of hazardous wastes. The waste will be mixed, including medical, oily wastes, woods and laboratory wastes. Primary combustion Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone Secondary combustion Residence time in the secondary chamber not less than 2 seconds Both primary and the secondary temperatures maintained until all the waste has been completely combusted Chimney Chimney with a minimum height of 4 meters above ground level Minimum exit velocity of the emissions not less than 10 metres/second Temperature Warnings Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature General Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter height Incinerator model A Burn Rate 65kg/h minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time – 2 Seconds Fuel – Diesel/LPG/LNG, please…

Read more

Incinerator for Animal Crematory Pig Farm Model A1200 *** 3 sets Burners *** Good for animals or big pets *** Double Combustion chamber *** stainless steel chimney *** Italy made oil burners *** 1200Liters(1.2m3) big chamber Model A1200 Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 100 kgs/feeding Primary Combustion Chamber 1200 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 34.4 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 130x100x90cm (primary chamber) External Dimensions 220x180x360cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 500 Liters Door Opening 55 x 80cm Chimney Length 10.0 Meters Chimney Type Stainless Steel Equipment Gross Weight 7500 kgs Operation Technical Specifications Primary Chamber Temperature 800℃–-1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower…

Read more

Pet Cremation Market Analysis in Australia and Demand for Incinerators Market Overview Australia has witnessed steady growth in the pet cremation sector over the past decade, driven by: Rising pet ownership: Over 69% of households now own pets (dogs, cats, birds, small mammals). Shifts in cultural attitudes: Owners increasingly view pets as family members and choose professional aftercare services. Urbanization: Limited backyard burial space in cities like Sydney, Melbourne, and Brisbane has boosted demand for cremation services. As a result, the market for pet aftercare―including individual and communal cremations―has become a niche but stable industry. Structure of the Pet Cremation Sector Australia’s pet cremation market consists mainly of: Independent, privately owned crematoria. Veterinary clinics that partner with regional cremation service providers. Mobile and small-scale pet cremation operators, especially in rural areas. Notable private service providers include: Patch & Purr Pet Cremations (NSW) Pets in Peace (Queensland) Passing Paws Pet Cremations…

Read more

*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto. control *** Italy made oil or gas burner(diesel oil/natural gas/lpg) *** temperature display and control *** high temperature firebrick,etc Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes…

Read more

Single and Dual Chamber Medical Incinerator.durable and highly efficient incinerators with various capacities for hospital/medical waste, cremation and other solid waste treatments.   Chamber Double Burning Rate      10 kg per hour (for two incinerators) Burning Rate     20 kg per hour (for three incinerators) Loading   Method   Manual No of Burners   Single for 10 kg/hour and Double for 20 kg per hour Fuel                    Diesel and Natural Gas Warm Up Time    Not more than 20 minutes Temperature controller   Digital Power Supply      Single Phase 220V Chimney Height    20 feet from ground level ·         50kg per hour ·         Option for  medical waste. Type Single Chambered Cylindrical Feed Material Papers, Cartons wastes Capacity 1000 Kg/Day Burning Capacity 125 Kg/hr Design Standards Generally confirming to IS Standards Type of burning operation Zero Fuel System Combustion Chamber Type Cylindrical Dimension 1.25 m Dia (Approx) x 1.2 m Height (Approx) Temperature 400 – 600 °C MOC Chrome Alloy Steel,…

Read more

*** Double Combustion Chamber *** PLC auto control operation *** stainless steel chimney *** smoke filter chamber *** Italy oil/gas burner *** whole design, mini. installation working *** cheaper cost *** long lifetime design *** better material and spare parts Items/Model TS30(PLC) Picture   Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) Average 16 Gas Consumption (L.P.G, m3n/Hour) Average 11.7 Temperature Monitor Four Digital Display Temperature Protection Yes Oil Tank 100L or More(Optional) Feed Door 55x50cm Chimney 5Meter or More(Optional) Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 4000kg External Dimensions 175x120x140cm Item Specification Model TS30 PLC Main Product List per…

Read more

3 Medical Waste Incinerator of 20 kg/hr capacity with dual burner.Medical Waste Incineration Systems. i’m interested to destroy about 200 kg remains. a Medical Incinerator project for Tehran municipality. Our purpose for this project is to establish a plant in order to incinerate Medical waste with 50 ton/day capacity. a incinerator with 100 kg / hour burning capacity. And it should work on diesel fuel, 2 chamber. Waste management Incinerator *External diameter at base 6ft 1.8m *External diameter at top 4 1/2ft 1.35m *Internal diameter at base 3ft 0.9m *Internal diameter at top 3ft 0.9m *Thickness of wall at base 18cm *Thickness of wall at top 9cm *Perpendicular height of wall 4ft *Height of Iron bars from grate above ground 1ft Material Required *Puddle swish *5 or 6 Iron bars about 4 1/2ft 1.35m long each *Quantity of large stones for foundation *2 empty kerosene tins for making vent holes…

Read more

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Average 20 kgs per feed Burning Rate Average 10 kgs per hour Burning Time per Feed 2 hours Voltage 220V Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour External Dimensions 100 x 100 x 160cm (mainbody) Internal Dimensions 50 x 50 x 80cm(Primary Chamber) Waste combustion chamber 200Liters Post Combustion Chamber 100Liters Oil Tank Capacity 50 Liters Door Opening 35 x 35cm Chimney 3.0M Gross Weight 1000kgs Chamber Material Refractory Concrete Max. Heat Value 126,000Kcal/Hr. Operation Technical Specifications Chamber temperature 8000C -10000C Chamber Anti-Rate 13500C Residency time 0.5 Sec. Burning efficiency >98% Waste Lower Calorific Power 3000Kcal HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-02-08

Carburant Diesel Capacité (M3) 1.92 Ave Capacity 1200kg Consommation (litre/heure 12 Dimension externes Longueur (mm) 3110 Largeur (mm) 2150 Hauteur (mm) 3200 Ouverture Porte 1000×2000 Dimension internes Longueur (mm) 2200 Largeur (mm) 1050 Hauteur (mm) 800 Opération. incinerator small to medium waste dispossal for about 150-200 municipal waste from shopping mall, office and residential. The waste most consist of vary materials plastics, rubber, paper, grass, leaves, woods, fruits, packaging carton, and many others Minimum température d’opération 950 Maximum température d’opération 1320 Température de suivi oui Thermostat oui Ventilateur oui Chambre de combustion secondaire 2 secs garantie minimum 12 mois Carburant Diesel Capacité (M3) 1.18 Ave Capacity 750 kg Consommation (l/h) 6 Dimension externes Longueur (mm) 3110 Largeur (mm) 1800 Hauteur (mm) 3300 Ouverture Porte 770×2000 Dimension internes Longueur (mm) 2100 Largeur (mm) 700 Hauteur (mm) 800 Opération. incinerator small to medium waste dispossal for about 150-200 municipal waste from shopping…

Read more

Item Specification Model YD-30C (customer made model) Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 units Oil Tank (if oil fuel): 100Liters Model YD-30C Feed Capacity Average 50 kgs per feeding Burning Rate Average 30 kgs per hour Burning Time per Feed 2 hours Voltage 220V/380V Power 6 Kw Fuel Natural Gas Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 10.2-20.0 Kgs/Hour Fuel consumption (Gas) 12.2-24.0m3/Hour External Dimensions 170 x 140 x 190cm (main body) Internal Dimensions 55 x 55 x 85cm(Primary Chamber) Waste combustion chamber 250Liters Post Combustion Chamber 140Liters Oil Tank Capacity 100 Liters Door Opening 38 x 48cm Chimney 5.0M Gross Weight 3300kgs Chamber Material Refractory Concrete Max. Heat Value 200,000Kcal/Hr. Operation Technical Specifications Solid Chamber…

Read more

110/1429