Category Archives: Blog

RECYCLABLE WASTE    PLASTIC (NON-PVC)     218,693 CARDBOARD     85,046 PAPER     4,956 PVC     15,115 HAZARDOUS WASTE    MEDICAL WASTE     1,084 SOLID WASTE CONTAMINATED WITH HYDROCARBONS     300,680 USED ENGINE OIL FILTERS     85,423 HYDROCARBON-CONTAMINATED SOILS     88,680 ORDINARY WASTE    FIBERS     14,078 USED AIR FILTERS (AUTOMOTIVE AND SIMILAR)     23,149 PERSONAL PROTECTIVE EQUIPMENT (PPE), INCLUDING CONTAMINATED CLOTHING AND SIMILAR DEBRIS     130,861 Pig corpses / stray dogs and larger animal carcasses cheap incinerators – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export. Note: Similar Technology and / or Tenderers Proposals are welcome. Within the framework…

Read more

Technical specification for burning machine,animal waste incinerator manufacturer 1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided. 2.Warrantee:  booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the customer. 3.All needed electric and water connections must be provided. 4.Both systems must be of high quality and must be environmental friendly. 5.The capacity of each system should be up to 100 kg/hr. 6.The system must have automatic feeding. 7.Each system must consists of two burning  rooms, one primary room for burning the drug and another room for burning the gases  that emit as a result of primary burning. 8.The…

Read more

Waste Incineration HICLOVER Model TS75  Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average 16.9 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 100L Feed Door 99x91cm Chimney 3Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 4500kg External Dimensions 2.30mx1.30mx2.55m 15kg-20kg LPG driven Clinical waste incinerator to burn highly infectious materials 100kg per hour *medical incinerator* is needed in the size of a *20ft container.*  100Kg/Hour Burning rate with        with Secondary burning Capacity Je suis intéressé par votre produit Longue durée de vie Pet Crematory (YD-15), je veux savoir plus de détails sur: Veuillez me…

Read more

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25% ·         Estimated ash residue: 5-10% ·         Nominal capacity: 30Kg/hour batch load ·         Secondary chamber: 0.5 second @ 850oC ·         Compact laboratory style ·         Two combustion chambers ·         Ecologically friendly ·         Up to 50kg of waste / hour ·         To be used for animals

medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas Consumption (m3/hour) average 10.1m3/hour Temperature Monitor Yes Temperature Protection Yes Oil Tank 100L Feed Door 30x30cm Chimney 5 Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 1500kg External Dimensions 140x90x120cm hazardous waste disposal companies HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-06-30

Item Specification Model YD-30C Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Automatic PLC controller incinerator plant with Dual heat burners and dual chamber. Burning capacity up to 30 Kg per hour. Water showering cyclone air cleaner Stain less steel 304 grade sheet for water scrub chamber Time up to 250 mints. Fully automatic electric control circuit with timers Primary temperature 800-1000 deg C Secondary temperature1000-1200 deg C Manual loading /unloading Automatic start at power fail during process Fast temperature rise control automatic detects fast burning materials and save burner fuel consumption by turn off /on burner automatically. Suitable for waste of hospitals Number of burner   2 Nos Voltage  380V 50Hz Operational enjoinment         …

Read more

In a simple design with a metal steel drum electric. including: A cage for receipt of biomedical waste; A combustion chamber with fireplace with a filter to retain ashes; A cover; An air supply; A turbine  allowing the supply of the air. Combustion temperature: 1800 ° C. Compliance with European standards. Comes with all necessary accessories Supply of incinerator model PDR-18 with: ·        Capacity 100 kg/hr of waste containing up to 85% moisture ?      Two combustion chambers ·        Two fully automatic, oil fired, pressure jet burners ·        Panel board ·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve. Type: for animals waste Capacity: 30 kg per hours for a maximum load of 120 kg. GLP Gas Voltage: 110V-120V Semiautomatic control board Stainless steel chimney, 3.5 meters above the incinerator. High temperature painting for all the incinerator. Front door for loading and unloading. Fuel    Diesel Oil…

Read more

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 03 sets Oil Tank (if oil fuel): 500Liters Design for Pets Cremation Business Movable platform & Auto. Door & Fire/Flame Checking Hole Independent Position for Small Pet HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-06-28 https://www.hiclover.com/wp-content/uploads/2020/06/Large-Capacity-Animal-Pet-Cremation-HICLOVER-Model-A1500-with-E-Power-Auto.-Door.mp4

The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated. At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table: hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center. In Transit and Sorting Center one laboratory must be considered. In this center, waste will be classified in two groups: –    Unsuitable for burning –    Suitable for burning Unsuitable waste for burning can be divided into the 4 categories: –    Buried materials –    Materials (wastes) that need to be stabilized before buried –    Materials (wastes) that can be sold. –    Wastes that can be returned to petrochemical. Suitable wastes are classified into…

Read more

Model YD-30 Mobile Type Picture   Burning Rate Average 30 kgs/hour Feed Capacity Average 60 kgs/feeding Chamber Main Body Stainless Steel Mobile Function With Wheel and Brake Primary Combustion Chamber 280 Liters Secondary Combustion Chamber 150 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 1.5 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 13.3 kg/hour Internal Dimensions 80 x 60 x 60cm (primary chamber) External Dimensions 125 x 90 x 260cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 100 Liters Door Opening 50 x 50cm Chimney Length 2.0 Meters Chimney Type Stainless Steel Equipment Gross Weight 1600 kgs Operation Technical Specifications Primary Chamber Temperature 800℃–-1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower Calorific Power 3000Kcal HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]…

Read more

20/1427