medical waste incinerators manufacturers
chemical agents to be utilized: 10% heptyl (unsymmetrical dimethylhydrazine) water solution, heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration, 10% azotic (nitric) acid water solution, azotic (nitric) acid vapour with concentration up to 1.1 kg/m3; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800?C to +1200?C; 4. performance: ? vapour capacity: 70 to 200 m3/h, ? water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; 7. overall dimensions shall allow for mounting the unit on a vehicle chassis. medical waste incinerators manufacturers General Specifications 6mm plate steel sheel construction 11cm 1400 o C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 o C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg / hr Primary Chamber-1607 L…
Waste Incineration Treatment BURNING RATE : 100-150kgs per hour HICLOVER TS150
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : MAXIMUM 3HRS FUEL TYPE : FUEL OIL ( DIESEL ) FUEL CONSUMPTION IN LTRS/HR : average 14 RESIDNECY TIME IN SECONDARY CHAMBER : 2 STAGES Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 100-150 kg/hour Feed Capacity Average 750kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate Paint for outside face 800°C Rate Combustion Chamber 1570L Internal Dimensions 150x100x105cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/230V 50/60Hz Power 0.9Kw Oil Consumption (Liter/hour) Average 14(D.O) Gas Consumption (m3/hour) *** Temperature Monitor Digital…
Pet Crematory HICLOVER A600
Model A600, crematorium manufacturers Internal Dimensions 130 x 70 x 65cm Suit for Animal Cat – yes Dog – yes Pig – no Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 units Oil Tank (if oil fuel): 200Liters dog cremation urns Model A600 Picture Feed Capacity Average 30 kgs per feeding(animal) Burning Rate Average 15 kgs per hour(animal) Voltage 220V Power 0.59Kw Fuel Natural Gas or Diesel oil or LPG Gas Burner Italy Burner Feed Mode Manual Feeding Fuel consumption (Oil) 10.0-16.0 Kgs/Hour Fuel consumption (Gas) 10.0-15.0m3/Hour External Dimensions 175 x 100 x 180cm (main body) Internal Dimensions 130 x 70 x 65cm(Primary Chamber) Waste combustion chamber 600Liters Post Combustion Chamber 200Liters Oil Tank Capacity 200 Liters or More(Optional) Door Opening 50 x 60cm Chimney 5.0M…
medical waste incinerator
medical waste incinerator: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: 50 Hz Feeding: automatic Ash 1 leftovers removal: Automatic Fuel gas filtration system: Yes Warranty: 12 months Staff training: Operator & Maintenance staff Operation and service manuals: 3 sets each Especifica??es Gerais 6 mm plate steel sheel construction 11cm 1400°C refractory Liner temperature controlled Burners secondary combustion burners interlock switch on load doors separete ash door one secondary residence @ 1000°C 400°C silicone Based finish paint alloy temperature sensor factory wired and tested Capacity 20kg/hr primary Chamber 1607 L Hearth area 1.36 aq.m Secondary Chamber 694L Primary burner (oil) 420.00btu Secondary burner (oil) 900,000btu Secondary combustion 1/6 hp Exhaust…
Mobile Containerized Waste Incinerators HICLOVER CA-200
Mobile Containerized Waste Incinerators pets or human cremation emergency use Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x 100cm (primary chamber) External Dimensions 290 x 200 x 170cm (primary chamber) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 500 Liters Door Opening 90 x 90cm Chimney Length 5.0 Meters Chimney Type Stainless Steel Equipment Gross Weight 9000 kgs(with container) Operation Technical Specifications Paimary Chamber Temperature 800℃–1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower Calorific Power 3000Kcal HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-06-27
medical waste diesel incinerator
medical waste diesel incinerator Burning Rate:47.5–50kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash post 100kg:Max 3.8kg Device for preventing infectious spatter and/or cross-contamination by safely sterilizing needles, rings, etc. by infrared heat. Electrical characteristics 1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 type. 2) Protections against over-voltage and over-current line conditions. 3) Compliance with applicable Haitian standards and regulations. Operational characteristics 4) Fast complete sterilization in around 5-7 s. 5) Fully isolated quartz/ceramic tube, to grant safety for the user (no open flame). 6) Working temperature around 820°C. 7) Mounted on a stable base, as per example below.
Incinerator with 1 or 3 section type wet scrubber
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity. Model YD-150 Picture Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Wet Scrubber System(3 Section Type) Feed Mode Manual Voltage 380V Power 9.0 Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 24 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 150 x 100 x 96cm (primary chamber) External Dimensions 240 x 170 x 380cm(without chimney/wet scrubber) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 300 Liters Door Opening…
Incinérateurs de Déchets Médicaux pour les Projets d’Éducation Médicale et de Coopération Hospitalière en Afrique Francophone
Incinérateurs de Déchets Médicaux pour les Projets d’Éducation Médicale et de Coopération Hospitalière en Afrique Francophone Introduction : L’essor de l’éducation médicale en Afrique Dans des pays comme le Cameroun, le Sénégal, le Mali et le Togo, l’expansion des universités médicales et hôpitaux universitaires joue un rôle essentiel dans la formation de la nouvelle génération de médecins. Ces établissements accueillent chaque année des milliers d’étudiants, de patients et de projets de recherche, générant des volumes importants de déchets biomédicaux. Pour assurer un environnement sûr et conforme, il devient indispensable d’intégrer des incinérateurs de grande capacité dans les projets d’éducation et de coopération hospitalière. Défis liés aux déchets médicaux dans les hôpitaux universitaires Les hôpitaux universitaires ne produisent pas seulement des déchets classiques, mais aussi : Déchets infectieux issus des salles d’opération et des laboratoires. Plastiques médicaux jetables utilisés dans les formations cliniques. Objets tranchants et piquants manipulés par des étudiants…
waste incinerator manufacturers from china
Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for greater efficiency and emissions control. Waste Type and Burn Rate Designed specifically for use by poultry farmers, sheep farm owners, abbatoirs and for pet cremation. The incinerator will burn up to 50kg of waste per hour (up to 150kg burn Construction Mild steel welded fabrication consisting of sheet steel and structural section supports. Lining Monolithic high grade refractory concrete with high grade insulation backing. Burners Fully automatic, high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted. Loading – Ash removal Manual ash removal from the primary chamber. (Ash doors are available on…
DIESEL FIRED INCINERATOR, WITH 1000 LTR FUEL TANK AND 6M CHIMNEY
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1000L Feed Door 2.04 x 1.06 M Chimney 3Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 9000kg External Dimensions 3.00mx1.60mx3.00m (without chimney) INCINERATION IS A WASTE TREATMENT PROCESS THAT INVOLVES THE COMBUSTION OF ORGANIC SUBSTANCES CONTAINED IN WASTE MATERIALS. INCINERATION AND OTHER HIGH-TEMPERATURE WASTE TREATMENT SYSTEMS ARE DESCRIBED AS “THERMAL TREATMENT”. INCINERATION OF WASTE MATERIALS CONVERTS THE WASTE INTO ASH, FLUE GAS AND HEAT. THE ASH IS MOSTLY FORMED BY THE INORGANIC CONSTITUENTS OF THE WASTE AND MAY TAKE…