medical incinerator manufacturer
1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accounting for the air supplied through burners. Provision shall be made in the primary chamber to measure the water column pressure. 2. Capacity : up to 4000kg burn not less than 500 kg /hr 3. medical incinerator manufacturer The refractory lining of the chamber shall be strong enough to sustain minimum temperature of 1000dc in the primary chamber and 1200 dc in the secondary chamber. The refractory& insulation bricks shall have minimum 115mm thickness each & conform to IS:8-1983 & IS:2042-1972 respectively. 4. The incinerator shell shall be made of SS/MS plate of adequate thickness (minimum…
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-04-10
laboratory incinerator
the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) , as well as biologically hazardous waste Products in the fuel stove . ? Opening Doors – the closure and fixation automated system , Which are managed remotely by the operator . ? designed to work in long mode and fast Action ( Quick Start EP – i) ? Fully mobile – mounted on wheeled chassis Even during the operation . Incinerators must be provided As standard equipment a special truck air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. ? must be a two-chamber incinerators, primary and secondary Fuel stoves ? The waste products to reduce the initial volume Possible to minimize (approximately 5% sterile ash Form). Incinerators should be provided in the fuel tank (diesel ) ? The minimum capacity…
Algeria’s Healthcare Waste Challenge and the Role of HICLOVER TS100 PLC Incinerators
Algeria’s Healthcare Waste Challenge and the Role of HICLOVER TS100 PLC Incinerators Growing Pressure on Medical Waste Management in Algeria Algeria, like many North African nations, is facing rising pressure to manage medical and hazardous waste in line with global environmental standards. Hospitals, vaccination programs, and laboratories generate increasing volumes of infectious waste, sharps, pharmaceuticals, and chemical residues. Traditionally, open burning or small, inefficient furnaces were used, but these practices are no longer acceptable under modern regulations. Algeria’s Décret exécutif n° 06-198 outlines requirements for waste incineration, and international donors increasingly expect alignment with EU Directive 2010/75/EU (IED) standards for emissions. EU-Level Emission Standards as a Benchmark The European IED directive sets strict limits: CO ≤ 50 mg/Nm³ Total dust ≤ 10 mg/Nm³ HCl ≤ 10 mg/Nm³ or ≥97% removal HF ≤ 1 mg/Nm³ or ≥97% removal SO₂ ≤ 50 mg/Nm³ or ≥97% removal NOx ≤ 200 mg/Nm³ for biomedical…
Medical Incinerator Manufacturers in Stock ready for shipping
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour optional) Feed Capacity Average 750kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Main Body Steel 8mm thickness Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate Paint for outside face 800°C Rate Combustion Chamber 1570L Internal Dimensions 150x100x105cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/230V 50/60Hz Power 0.9Kw Oil Consumption (kg/hour) Average 20.4-28.0(D.O) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 300L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st.…
medical incinerators
● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power consumption to be stated ● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste ● Solid waste reduction in range of 90-97% ( should be routinely achieved) · General wastes produced on a daily basis include paper, plastic, organic materials, boxes, plastic containers, leaves, etc; · Total waste produced per day: 10-12 tonnes; · Hours of Operation: 10 hours a day; · Fuel requirement: Diesel or waste oil preferred but LP gas will be considered; Fuel options Oil Fuel consumption (diesel) 10 litre/hour Average Capacity …
Medical Waste ncinerators for Hospital 10-500kgs per hour
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃…
small scale incinerator
Incinerators Biological waste disposal system (incinerator) Incinerator must meet the following specifications: – Combustion capacity (kW) = 581 +/-10% – Combustion capacity (kcal/h) = 500,000 +/-10% – Max. l/h (at approx.. 50% water content) = 100 +/-10% Further specifications will be provided with the inquiry. The incinerator shall be fully self contained. The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h. It should be able to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification : Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator…
Hospital Medical Waste Incinerators
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks 7m3 4500 kgs Shanghai Port TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks 10m3 6000 kgs Shanghai Port TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks 13m3 7500 kgs Shanghai Port YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 3m3 1200 kgs Shanghai Port YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 6m3 2000 kgs Shanghai Port YD50C average 50kgs per…
Tanzania Incinerator Project Tenders and Hospital Waste Management Solutions with HICLOVER
Tanzania Incinerator Project Tenders and Hospital Waste Management Solutions with HICLOVER In East Africa, and particularly in Tanzania, safe disposal of biomedical waste remains a priority for both government agencies and international donors. Recent Tanzania incinerator project tenders reflect growing demand for modern, containerized solutions that combine high-temperature combustion with modular plant flexibility. Hospitals, district clinics, and donor-supported health facilities require robust waste treatment technology to reduce risks from sharps, infectious materials, and pharmaceutical residues. HICLOVER has emerged as a trusted choice for these needs, providing containerized and mobile systems specifically tailored to the challenges of African healthcare waste management. Hospital Waste Management in Tanzania Tanzania’s healthcare sector generates a diverse stream of waste, from used syringes and sharps containers to pathological and pharmaceutical residues. Traditional open-pit burning or poorly designed local incinerators are no longer acceptable under Tanzania’s National Environmental Management Council (NEMC) guidelines. Instead, hospital waste management in Tanzania…