Containerized Mobile Incinerator Medical Waste Incinerator Model CA50
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption (Oil) Average 16.9 Kgs/Hour Internal Dimensions 100x80x70cm (Primary Chamber) External Dimensions 230 x 130 x 155cm (main body) Waste combustion chamber 560Liters Post Combustion Chamber 280Liters Oil Tank Capacity 200 Liters Door Opening 70 x 50cm Chimney 5.0M Gross Weight 4500kgs Chamber Material Firebrick ,Refractory Concrete Max. Heat Value 166,000Kcal/Hr. Operation Technical Specifications Solid Chamber temperature 8000C -10000C Gas Chamber temperature 10000C -12000C Chamber Anti-Rate 17500C Residency time 2.0 Sec. Burning efficiency >98% Waste Lower Calorific Power 3000Kcal WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet…
WASTE CATALOGUE AND HAZARDOUS WASTE LIST
1 Incinerator 30 =KG burn/h and it must have a Scrubber. 2 Incinerator must have Electrical Plastic Shredder for cutting of glass bottle,surange of Medicine. 3 Incinerator must have Electrical Auto Clave or Microwave for Dis Infection separately with incinerator. 4 Incinerator must have Double Chambers first Chamber must gave 800C temperature and secondary Chamber working 1200C temperature. 5 Incinerator in out place must have a Parameter to show inner temperature of incinerator. 6 Incinerator must work in two systems Electric and fuel describe in which kind of fuel works. Note we want it works on diesel fuel and electric also.for a small pig slaughterhouse project in Vietnam we are looking for a solution to destroy safely inedible and seized animal products. As the slaughtered pigs are consumed by more than 90% (from hooves to head, blood, etc) the waste volume is quite small even in slaughter-points with up to…
Medical Waste Incinerator for Coronavirus Disease
Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care waste for laboratories, small clinics, and hospitals treating patients of the Novel Coronavirus (COVID-19) such as linens, sharps, gauze, gowns, etc. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner…
Hospital Waste Management
Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description Minimum Requirements Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length Width Height Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe,…
Large General waste incinerator Burn Rate up to 250kg per hour
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1000L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 11000kg External Dimensions 400x210x300cm(without chimney) HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-03-22
hiclover incinerator 100-150kgs per hour
Model YD-100 Picture Burning Rate 100-150 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 Liters Feed Mode Manual Voltage 220V/380V Power 2.5Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 28 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 180x115x98 cm (primary chamber) External Dimensions 270x185x280cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 200 Liters Door Opening 55 x 80cm Chimney Length 6.0 Meters Chimney Type Steel Equipment Gross Weight 9000 kgs Operation Technical Specifications Primary Chamber Temperature 800℃–-1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower Calorific Power 3500Kcal HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-03-22
Incinerator for hospital waste management
Incinerator for hospital waste management with the following features: • In high temperatures (pyrolytic incinerator two chambers with temperatures ranging from 950 º C to 1320 º C; • Ability to destruction of 400 to 600kg per hour; • Capable of destroying microorganisms; • Drain ash; • Drain needle and glass crusher; • Porch with tap water for hand washing and decontamination; • Observe the issue of environmental quality standards, emissions fluent and regulation on the issue of waste;install large incinerator to one of the biggest veterinary hospital in KSA so if you will support us with one unit (large incinerator) and environmental with onsite training , the capacity for the unit is 2000 Kg for cattle , horses and farm animals also suitable to all animal waste types , we need it diesel fired . OES-Industrial MultiWaste Incinerator System (Solid/Liquid) Scope of the Work: Design, installation and commissioning of…
Mobile Cremation Equipment
Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 230 x 100 x 90cm (primary chamber) External Dimensions 290 x 200 x 170cm (primary chamber) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 500 Liters Door Opening 90 x 90cm Chimney Length 5.0 Meters Chimney Type Stainless Steel Equipment Gross Weight 9000 kgs(with container) Operation Technical Specifications Paimary Chamber Temperature 800℃–1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower Calorific Power 3000Kcal Mobile crematorium HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-03-22
INCINERATOR DIESEL DRIVEN
INCINERATOR, DIESEL DRIVEN waste type : HEALTH CARE WASTE Waste calorific value : 4000KCAL/KG Moisture Content : 10-25% Nominal Capacity : 50Kg/Hour batch load Secondary Chamber : 2 Seconds @ 850degrees C The primary combustion chamber must ensure minimum exit temperature is not less than 850 degrees C. INSULATION Calcium Silicate Limiting Continuous service limit 1000 degrees C. Thickness 25mm THROUGHPUT 50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of 120kg/MCubed for general waste and 160kg/MCubed for health care waste.
Large Size Burning Rate:150-200 kg/hr Solid Waste Equipment Primary and Secondary Combustion Chamber Incinerator
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 28 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1400L Feed Door 90x80cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–-1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 15000kg External Dimensions 400x210x300cm(without chimney) The air supply should be controlled efficiently; Flame contact with all the gases should be achieved; The minimum combustion temperature of the primary chamber should not be less than 850°C; The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply. The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm. The following conditions should be met in…