pet crematory
Waste Incinerator vs pet crematory a.) incinerator for waste. VS cremator for animalsanimal-cremation b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns.pet-cremation-urns c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation is personal business more.265_00066_23SEPT.jpg f.) waste incinerator with small-large scale capacity. VS pet cremation with regual pet size or weight g.) waste incinerator feeding door small or big. VS pet cremator feeding door match with pet size h.) waste material with or without fat. VS pet body with fat.cremation-ash i.) waste incinerator with or without exchange feeding door. VS pet cremator better with exchange feeding door.pet-cremation-in-incinerator-chamber Tweet
animal waste incinerator
the animal waste incinerator design with 2 or 3 combustion chamber, different feeding door and combustion size for different animal size. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90 Oil Tank(Liters) 200 200 300 300 Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80 Chimney (M) 5 5 5 10 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES…
animal incinerator cost
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world. animal incinerator cost is key point for pet cremation business owners. our pet incineration equipment made with double combustion chamber, waste oil collect function, movable feeding door. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90 Oil Tank(Liters) 200 200 300 300 Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80 Chimney (M) 5 5 5 10 Chimney…
animal waste incinerator manufacturer
we are animal waste incinerator manufacturer, the combustion chamber volume up to 5.5m3 for big animal and also make small incinerator for pets and small animals. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90 Oil Tank(Liters) 200 200 300 300 Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80 Chimney (M) 5 5 5 10 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter…
china animal cremation
Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management. Tweet
HICLOVER Needle Incinerators-Syringe and Destroyer-Needle Destroyer
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again. Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube. Model SYC19, Price: $110usd/set, MOQ: 5 sets. EXW factory term(donot including shipping cost) Purchase email: [email protected] Qustion1: If request 1-4 set only, how to do? Answer: We will plus $50-$200usd fee per order. Qustion2: If request more than 5 sets only, any discount? Answer: We will supply discount quotation accordingly. Related Small scale incinerator for hospital 5kgs 10kgs 20kgs and 30kgs per hour average What are the objectives…
hospital incinerator manufacturers
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to: Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum capacity of primary chamber = 10cubic meters Burn rate (rate of waste incineration) = 10 kg per hour Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash. The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006. Scope Of Work The work specified in the contract will include. Supply, install and commission an incinerator as provided in the technical specifications Provision for adherence to OSHA and other statutory requirement relating to Health…
animal incinerators for sale
animal incinerators for sale, movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal. Model A900 Function movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal. Burning Rate Average 30 kgs/hour Feed Capacity Average 80 kgs/feed Primary Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 0.7Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 31 kg/hour Gas Consumption (Natural Gas) Average 27 m3/hour Internal Dimensions 120 x 90 x 85 cm (primary chamber) External Dimensions 200 x 160 x 310 cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 300 Liters Door Opening 60 x 80cm Chimney Length 5.0 Meters Chimney Type Stainless Steel Combustion Chamber Material Refractory Concrete Cement(No Brick) Equipment Gross Weight 6000 kgs Operation Technical…
About Hiclover Medical Enviromental
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc. Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums. The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection. System solutions for medical waste environmental, including waste incineration, smoke emission treatment,…
Required Specifications for Mobile Incinerator
Operational Capabilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS SCRUBBING SYSTEM 95% REDUCTION OF SOLID WASTE OPERATE OFF DIESEL OR FUEL OIL CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD NO PRE-TREATMENT OF WASTE REQUIRED FIVE (5) YEAR COMPONENT WARRANTY Technical Specifications OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR SET UP AND INSTALLATION INSTRUCTION MANUALS BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION OPERATED AND TRANSPORTED…