Tag Archives: ca

High Temperature Protection Gloves and  High Temperature Protection Masks for incinerator operation Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber

Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L…

Read more

Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy technologies elastec incinerator hospital waste management Related how so i buy an incineration Baltur Burner BT14GW for waste incinerator spare parts oil burner What is the main advantage of incineration? What is incinerators used in hospitals?

50 bed hospital proposal model TS5 or TS10 incinerator 200 bed hospital proposal model TS50 incinerator we have more than 1000kgs per hour capacity incinerator. How does a hospital incinerator work? The incinerator comprises primary and secondary combustion chambers. The burning zone  of the primary chamber is accessible through a door at the front which lets in air and allows the operator to light the fire and remove the ash. The medical waste is dropped in through a loading door above the primary chamber. How is hospital waste disposed of? Two common methods of disposing of hospital-generated medical waste include incineration  or autoclaving. Incineration is a process that burns medical waste in a controlled environment. …  State regulations may mandate off-site incineration for certain types of waste. The main purpose of any medical waste incinerator is to eliminate pathogens from waste and  reduce the waste to ashes. However, certain types…

Read more

you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to know price, we only supply gas burner. if oil fuel, we supply oil system and oil tank already. installation, we assembly all we can do before leave and local working almost on chimney, control case, oil system as our indication guider on the machine. local site have to build a incineration operation house, simple type with concrete foundation. by now, covid19, we support online or video guide and free cost. medical waste trucks waste incinerator tanzania modern incineration technology ready mace incinerator the need for a hospital incinerator incinerator for hazardous waste construction manufacturers of fuel…

Read more

the hot sale small animal incinerator is A360 and the primary combustion chamber is 360Liters, the incinerator with 2 italy burner and 3 combustion chamber and also 1 smoke filter chamber. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs Primary Chamber (Liters) 200 200 250 400 Secondary Chamber (Liters) 140 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85 Oil Tank(Liters) 50 100 100 150 Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55 Chimney (M) 5 5 5 5 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES…

Read more

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. animal incinerators is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management. Items/Model A1500 A2400 A4000 A5500 Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr. Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs Primary Chamber (Liters) 1500 2400 4000 5500 Secondary Chamber (Liters) 500 1200 1500 1500 External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475 Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125 Oil Tank(Liters) 500 500 500 500 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Chimney (M) 10 10 14 14 Chimney Type…

Read more

All kindly pets owners hope their lovely dog or cat be in heaven after they leave us. We understand the special bond between pet and owner and believe that it should never be forgotten. Losing a pet can be devastating and we built our business so families can remember their pets forever. the range of pet incinerator prices from 10000 usd to 30000 usd. you have to confirm what size of the pet, cat or small dog or big dog or other big animal. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60…

Read more

generally, small incinerator means burning rate under 50 kgs per hour. we have incinerator 5kgs per hour, 10 kgs per hour,20 kgs per hour,30 kgs per hour,50 kgs per hour. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs Primary Chamber (Liters) 200 200 250 400 Secondary Chamber (Liters) 140 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85 Oil Tank(Liters) 50 100 100 150 Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55 Chimney (M) 5 5 5 5 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Combustion…

Read more

if you want to know animal incinerator price, the first is what size of animal will be cremation then we know what capacity incinerator is best for customer and other important point is the oil or gas cost, this according to small or big burner on the incinerator. the small burner less oil per hour but long time to burn out the animal. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90 Oil Tank(Liters) 200 200 300 300 Door Opening (cm) 48 x 60 50 x…

Read more

50/54