Tag Archives: power

SECTION V   TECHNICAL SPECIFICATIONS OF THE INCINERATOR   General Description   The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:   Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum capacity of primary chamber = 10cubic meters Burn rate (rate of waste incineration) = 10 kg per hour Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash. The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006.   Scope Of Work   The work specified in the contract will include.   Supply, install and commission an incinerator as provided   in the technical specifications   Provision for adherence to OSHA and other statutory requirement relating to Health…

Read more

animal incinerators for sale, movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal. Model A900 Function movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal. Burning Rate Average 30 kgs/hour Feed Capacity Average 80 kgs/feed Primary Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 0.7Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 31 kg/hour Gas Consumption (Natural Gas) Average 27 m3/hour Internal Dimensions 120 x 90 x 85 cm (primary chamber) External Dimensions 200 x 160 x 310 cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 300 Liters Door Opening 60 x 80cm Chimney Length 5.0 Meters Chimney Type Stainless Steel Combustion Chamber Material Refractory Concrete Cement(No Brick) Equipment Gross Weight 6000 kgs Operation Technical…

Read more

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management. General waste is an unwanted refuse material or substance. It may consist of materials from community or household activities (municipal, domestic or camp waste) or from industrial activities (manufacturing, mining or agricultural).waste incineration power plant,animal incinerator,garbage incinerators,Pet Incinerator Worldwide, the problem of waste accumulation is reaching threatening proportions. Landfill options are showing more and more weaknesses and are becoming extremely expensive. They are not an efficient solution. As a natural process, nature is converting landfill waste into highly dangerous matter.

Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.waste incineration companies,cremation mobile,incinerators waste,poultry incinerators,incinerator portable Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote…

Read more

Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor and Noise. …     Prevents the Production of Methane Gas. Incinerator Items/Model TS20(PLC) TS30(PLC) Burn Rate (Average) 20-30 kg/hour 30-50 kg/hour Feed Capacity(Average) 40kg/feeding 60kg/feeding Control Mode PLC Automatic PLC Automatic 1st. Chamber Composition Hot Face Thickness: ≥115 mm Thickness: ≥115 mm 55% of Al203 55% of Al203 1750°C Grade 1750°C Grade 2nd. Chamber Composition Hot Face Thickness: ≥200 mm Thickness: ≥200 mm 75% of Al203 75% of Al203 1790°C Grade 1790°C Grade Chamber Cold Face Material High Rate Refractory Ceramic Fiber High Rate Refractory Ceramic Fiber Other Parts Hot Face Refractory Heavy Duty…

Read more

Baltur Burner BT14GW for waste incinerator spare parts oil burner,  almost for incinerator capacity 50/100/150kgs per hour. 7.5-14.5kgs per hour diesel oil fuel 0.13Kw 16kgs per set Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto.…

Read more

Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L…

Read more

17/17