Tag Archives: sa

Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.waste incineration companies,cremation mobile,incinerators waste,poultry incinerators,incinerator portable Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote…

Read more

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber. *according to order * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane…

Read more

Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor and Noise. …     Prevents the Production of Methane Gas. Incinerator Items/Model TS20(PLC) TS30(PLC) Burn Rate (Average) 20-30 kg/hour 30-50 kg/hour Feed Capacity(Average) 40kg/feeding 60kg/feeding Control Mode PLC Automatic PLC Automatic 1st. Chamber Composition Hot Face Thickness: ≥115 mm Thickness: ≥115 mm 55% of Al203 55% of Al203 1750°C Grade 1750°C Grade 2nd. Chamber Composition Hot Face Thickness: ≥200 mm Thickness: ≥200 mm 75% of Al203 75% of Al203 1790°C Grade 1790°C Grade Chamber Cold Face Material High Rate Refractory Ceramic Fiber High Rate Refractory Ceramic Fiber Other Parts Hot Face Refractory Heavy Duty…

Read more

Baltur Burner BT14GW for waste incinerator spare parts oil burner,  almost for incinerator capacity 50/100/150kgs per hour. 7.5-14.5kgs per hour diesel oil fuel 0.13Kw 16kgs per set Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto.…

Read more

High Temperature Protection Gloves and  High Temperature Protection Masks for incinerator operation Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber

Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L…

Read more

50 bed hospital proposal model TS5 or TS10 incinerator 200 bed hospital proposal model TS50 incinerator we have more than 1000kgs per hour capacity incinerator. How does a hospital incinerator work? The incinerator comprises primary and secondary combustion chambers. The burning zone  of the primary chamber is accessible through a door at the front which lets in air and allows the operator to light the fire and remove the ash. The medical waste is dropped in through a loading door above the primary chamber. How is hospital waste disposed of? Two common methods of disposing of hospital-generated medical waste include incineration  or autoclaving. Incineration is a process that burns medical waste in a controlled environment. …  State regulations may mandate off-site incineration for certain types of waste. The main purpose of any medical waste incinerator is to eliminate pathogens from waste and  reduce the waste to ashes. However, certain types…

Read more

you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to know price, we only supply gas burner. if oil fuel, we supply oil system and oil tank already. installation, we assembly all we can do before leave and local working almost on chimney, control case, oil system as our indication guider on the machine. local site have to build a incineration operation house, simple type with concrete foundation. by now, covid19, we support online or video guide and free cost. medical waste trucks waste incinerator tanzania modern incineration technology ready mace incinerator the need for a hospital incinerator incinerator for hazardous waste construction manufacturers of fuel…

Read more

the hot sale small animal incinerator is A360 and the primary combustion chamber is 360Liters, the incinerator with 2 italy burner and 3 combustion chamber and also 1 smoke filter chamber. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs Primary Chamber (Liters) 200 200 250 400 Secondary Chamber (Liters) 140 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85 Oil Tank(Liters) 50 100 100 150 Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55 Chimney (M) 5 5 5 5 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES…

Read more

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. animal incinerators is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management. Items/Model A1500 A2400 A4000 A5500 Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr. Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs Primary Chamber (Liters) 1500 2400 4000 5500 Secondary Chamber (Liters) 500 1200 1500 1500 External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475 Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125 Oil Tank(Liters) 500 500 500 500 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Chimney (M) 10 10 14 14 Chimney Type…

Read more

30/33