Tag Archives: use

waste incinerator means incineration the waste by incineration. we supply waste incinerator for medical hospital waste, pet cremation and animal incineration and other solid waste treatment. the waste incinerators have 2 combustion chamber, the first burner burn the waste in the primary combustion chamber and the other burner burn the smoke from primary combustion chamber. the smoke will be filtered by smoke filter chamber and then out. the waste incinerator use stainless steel chimney which is long life time and all the burner made in italy. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode…

Read more

incinerator 500kg per hour, which model is YD500. the fuel type is diesel oil or natual gas or LPG. this model incinerator burning rate is 500kgs per hour and the feeding capacity is average 800kgs per time, accordingly to detail waste material. YD500 is also suit for big animal cremation and we supply custom made incinerator accordingly to different use. incinerator 500kg per hour is average capacity for medical waste and this is also suit for hospital waste, animal cremator and other solid waste management. Model YD-500  Burning Rate 500 kgs/hour Feed Capacity 800 kgs Primary Combustion Chamber 4000 Liters Secondary Combustion Chamber 1500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 2.24Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 31–59.1 kg/hour Gas Consumption (Natural Gas) 19.2–64.2 m3/hour Internal Dimensions 257 x 147 x 108cm (primary chamber)…

Read more

portable incinerator means a small incinerator so end user can move it to other place. we made portable incinerator and the weight under 2000 kgs, the burning rate from 5kgs per hour to 20kgs per hour. all designed with three combustion chamber and two oil or gas burner. this kind of portable incinerator is cheap cost for small waste out put. Items/Model YD-10C YD-20C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs Equipment Weight 2100 kgs 2100 kgs Primary Chamber (Liters) 200 200 Secondary Chamber (Liters) 140 140 External Dimensions (cm) 170x140x160 170x140x160 Internal Dimensions (cm) 55x55x65 55x55x65 Oil Tank(Liters) 50 100 Door Opening (cm) 38 x 48 38 x 48 Chimney (M) 5 5 Chimney Type Stainless Steel Stainless Steel Secondary Chamber YES YES Mix-Combustion Chamber YES YES Smoke Filter Chamber YES YES Combustion Fuel Oil/Gas Oil/Gas Residency Time 2.0 Sec. 2.0 Sec.…

Read more

small scale incinerator means small burning rate (capacity), average from 5kgs per hour to 20 kgs per hour. this kind of incinerator mainly for small hospital clinic or laboratory, etc. but all of them design with double combustion chamber to best waste treatment. some place or department, small scale incinerator is necessary for goverment rule request and the end user need a simple cheap equipment, you can contact with to design with more cheaper cost but simple for you. Items/Model YD-10C YD-20C YD-30C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs Primary Chamber (Liters) 200 200 250 Secondary Chamber (Liters) 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 Oil Tank(Liters) 50 100 100 Door Opening (cm) 38 x 48 38 x 48 38 x 48 Chimney…

Read more

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation  Company License No.,: 320105000138343  Taxation Certificate No.: 320105571573734  Export Business Certificate No.: 3201571573734  Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, what is a biological incinerator for pets, what is double chamber incierator, what is the average cost for a medical incinerator, what is the cost of a pet cremation incinerator, Animal Incineration, Pet cremation and other Solid wste. The capacity…

Read more

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *according to order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.  Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply…

Read more

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc. Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums. The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection. System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp,…

Read more

the animal crematory equipment function like other incinerators, but there are also some difference, some key point is door opening(we can feed the pet), oil or gas operation cost, moveable feeding door, smoke enviromental friendly, if we can collect ash, easy to use it, good service from pet incinerator manufacturer,etc. Items/Model A360 A600 A900 A1200 Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr. Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs Primary Chamber (Liters) 360 600 900 1200 Secondary Chamber (Liters) 200 200 300 500 External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360 Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90 Oil Tank(Liters) 200 200 300 300 Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80 Chimney (M) 5 5 5 10…

Read more

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again. Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube. Model SYC19, Price: $110usd/set, MOQ: 5 sets. EXW factory term(donot including shipping cost) Purchase email:  [email protected] Qustion1: If request 1-4 set only, how to do? Answer: We will plus $50-$200usd fee per order. Qustion2: If request more than 5 sets only, any discount? Answer: We will  supply discount quotation accordingly. Related Small scale incinerator for hospital 5kgs 10kgs 20kgs and 30kgs per hour average What are the objectives…

Read more

SECTION V   TECHNICAL SPECIFICATIONS OF THE INCINERATOR   General Description   The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:   Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum capacity of primary chamber = 10cubic meters Burn rate (rate of waste incineration) = 10 kg per hour Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash. The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006.   Scope Of Work   The work specified in the contract will include.   Supply, install and commission an incinerator as provided   in the technical specifications   Provision for adherence to OSHA and other statutory requirement relating to Health…

Read more

10/19