Tag Archives: www

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China.The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown area. Presently, incinerator line products market cover former Soviet Union area, Africa countries, Asia countries and middle east area.   From year 2010, we negotiated with updated technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Unfortunately, competition in other countries market, country discrimination and worries of intellectual property rights cause failure finally. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment in the world.

Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor and Noise. …     Prevents the Production of Methane Gas. Incinerator Items/Model TS20(PLC) TS30(PLC) Burn Rate (Average) 20-30 kg/hour 30-50 kg/hour Feed Capacity(Average) 40kg/feeding 60kg/feeding Control Mode PLC Automatic PLC Automatic 1st. Chamber Composition Hot Face Thickness: ≥115 mm Thickness: ≥115 mm 55% of Al203 55% of Al203 1750°C Grade 1750°C Grade 2nd. Chamber Composition Hot Face Thickness: ≥200 mm Thickness: ≥200 mm 75% of Al203 75% of Al203 1790°C Grade 1790°C Grade Chamber Cold Face Material High Rate Refractory Ceramic Fiber High Rate Refractory Ceramic Fiber Other Parts Hot Face Refractory Heavy Duty…

Read more

Baltur Burner BT14GW for waste incinerator spare parts oil burner,  almost for incinerator capacity 50/100/150kgs per hour. 7.5-14.5kgs per hour diesel oil fuel 0.13Kw 16kgs per set Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto.…

Read more

High Temperature Protection Gloves and  High Temperature Protection Masks for incinerator operation Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber

Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm Secondary Chamber 50L 110L 180L 280L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber Feed Mode Manual Manual Manual Manual Voltage 220V 220V 220V 220V Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9 Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2 Temperature Monitor Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L…

Read more

Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy technologies elastec incinerator hospital waste management Related how so i buy an incineration Baltur Burner BT14GW for waste incinerator spare parts oil burner What is the main advantage of incineration? What is incinerators used in hospitals?

50 bed hospital proposal model TS5 or TS10 incinerator 200 bed hospital proposal model TS50 incinerator we have more than 1000kgs per hour capacity incinerator. How does a hospital incinerator work? The incinerator comprises primary and secondary combustion chambers. The burning zone  of the primary chamber is accessible through a door at the front which lets in air and allows the operator to light the fire and remove the ash. The medical waste is dropped in through a loading door above the primary chamber. How is hospital waste disposed of? Two common methods of disposing of hospital-generated medical waste include incineration  or autoclaving. Incineration is a process that burns medical waste in a controlled environment. …  State regulations may mandate off-site incineration for certain types of waste. The main purpose of any medical waste incinerator is to eliminate pathogens from waste and  reduce the waste to ashes. However, certain types…

Read more

you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to know price, we only supply gas burner. if oil fuel, we supply oil system and oil tank already. installation, we assembly all we can do before leave and local working almost on chimney, control case, oil system as our indication guider on the machine. local site have to build a incineration operation house, simple type with concrete foundation. by now, covid19, we support online or video guide and free cost. medical waste trucks waste incinerator tanzania modern incineration technology ready mace incinerator the need for a hospital incinerator incinerator for hazardous waste construction manufacturers of fuel…

Read more

the hot sale small animal incinerator is A360 and the primary combustion chamber is 360Liters, the incinerator with 2 italy burner and 3 combustion chamber and also 1 smoke filter chamber. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs Primary Chamber (Liters) 200 200 250 400 Secondary Chamber (Liters) 140 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85 Oil Tank(Liters) 50 100 100 150 Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55 Chimney (M) 5 5 5 5 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES…

Read more

70/78